Industrial Ro 100 LPH
BASIS OF DESIGN (100 LPH)
1 PLANT INTRODUCTION: Water Treatment scheme is designed to produce product water at the flow rate of 100 LPH based on Reverse Osmosis Technology. Note : The proposed water treatment system can even work continuously for 8-9 Hrs per day leaving aside 0.5 - 1 Hrs for the recommended Backwashing of the Filtration system. 2 RAW WATER ANALYSIS (ASSUMPTED): The proposed Water Treatment System based on following Water Analysis,
|
Sr. No.
|
Parameter
|
Analysis Value.
|
|
1
|
Total Dissolved Solids
|
1000 ppm (Max.)
|
|
2
|
Turbidity
|
<1 NTU
|
|
3
|
Total Hardness
|
< 350
|
|
4
|
pH
|
7.5
|
|
5
|
Organics And Bacteria
|
NIL
|
|
6
|
Oil And Grease
|
NIL
|
|
7
|
Residual Chlorine
|
NIL
|
|
8
|
Temperature ( ̡̉C )
|
< 40.
|
|
9
|
Color
|
Color Less
|
|
10
|
Odor
|
Odor Less
|
|
11
|
BOD & COD
|
NIL
|
3 END WATER QUALITY:
|
TDS
|
< 50 ppm.
|
|
pH
|
7.0 +/ - 0.2
|
|
Turbidity
|
Nil.
|
|
Color
|
Nil.
|
4 RO PLANT OPERATING CONDITION:
|
Sr. No.
|
Parameter
|
Value.
|
|
1
|
Feed Flow Rate.
|
300 LPH
|
|
2
|
Product Flow Rate
|
100 LPH
|
|
3
|
Reject Flow Rate.
|
200 LPH
|
|
4
|
Recovery.
|
30 - 35 %
|
|
Sr. No.
|
Description
|
|
1
|
Raw Water Pump ( By Client)
|
|
2
|
Sand Filter
|
|
3
|
Carbon Filter
|
|
4
|
Anti Scaling Dosing System. ( for more then 1000 ppm TDS)
|
|
5
|
Micron Cartridge Filter ( 20 Micron & 5 Micron )
|
|
6
|
High pressure Pump
|
|
7
|
RO Module
|
|
8
|
RO Product water storage Tank. ( By Client)
|
|